Iris Management Suite
Technical Guide V1.7C 4/11/07
16
8 Sets the account
number used for
reporting system events
System events, which are not dialler specific, such as
dialler link fail are reported to the ARC on this account
number.
9 Dialler link IP address This is the IP address that will be sent to any dialler that
is told to use this Polling Engine as its main or backup. If
the Polling Engine sits behind an address translating
gateway or firewall, this must be the ‘public’ IP address
on the other side of the gateway.
Note – the facility to validate this address by making a
test call to the address entered is automatically offered.
Caution – it is vital that this address is correct or
diallers may not be able to communicate with the
system as required.
10 To tell which diallers to
accept polls from
Normally set to ‘Own Diallers’, i.e. diallers for which this
is the main Polling Engine, so that polls overdues are
only reported to the ARC from one Polling Engine. This
prevents possible confusion in the ARC if a dialler
temporarily polls into its backup Polling Engine due to
some transient IP network problem.
In the event of the main Polling Engine completely failing,
this can be set to ‘All Diallers’ to ensure that the Backup
Polling Engine now reports any poll overdues and keeps
the ARC updated.
11 Determines what is
shown in the Polling
Engine monitor window
‘All’ selects everything. ‘Normal’ prevents routine events
being displayed.
12 Exit options Remember that any changes will not be saved unless the
correct option is selected.
Seitenansicht 15